Directions for Use:
Full Strip Preparation
Strip the floor with an Ecolab stripper at the recommended use dilution. Rinse well and let dry.
Scrub and Recoat Preparation
Deep scrub with an Ecolab floor cleaner using a blue pad. Rinse and let dry.
Sealing the Floor
A sealer is not required with Phazer Stratus floor finish on most resilient floors. If a sealer is desired due to floor porosity (e.g., terrazzo) apply one or two coats of an Ecolab sealer. For protection against staining spills, apply one to two coats of Ecolab sealer.
Maintenance
Dust mop. Autoscrub or damp mop with Bright Speed Floor Cleaner or Bright Neutral Floor Cleaner and a blue pad. Burnish daily (four to seven times per week) with an ultra high speed, champagne/tan synthetic burnishing pad. Propane burnishing provides the best results.
Slip Resistance
Phazer Stratus floor finish is classified by UL as it relates to slip resistance.
Directions for Phazer Mobile System Use
Set-up
- Pre-rinse the applicator pad; wring out and center the pad onto the applicator head.
- Place a bag of product into the pack with the bag spout at the bottom of the pack and facing out. Lock the spout into position. Close the cover and secure the locking strap.
- Attach the delivery tube by rotating the tube connector onto the spout and hand tighten. Put on the pack and adjust the straps.
Application Method
- Plan your route to maintain a wet leading edge. Work in sections.
- Depress the lever on the applicator handle to dispense product as needed.
- Coats are most commonly applied at 1750 ft2/U.S. gallon (42 m2/L).
- Work the applicator pad through a small puddle of product to pre-load the pad.
- Outline the first section and fill in using an overlapping figure-8 pattern; overlap the outline.
- Start slowly and build speed over time to avoid ridges, splashing and missed areas.
- The average dry time before walking on floor will be 15-40 minutes; allow approximately 40 minutes between coats.
- Remove using any Ecolab floor finish stripper. Follow label directions.
Clean-up
- Remove the tube connector from the spout. Attach the tethered adapter. Activate the handle lever and hold the connector under running water. Rinse out the system thoroughly.
- Rinse the exterior of the bag spout.
- Immerse the applicator pad in water (do not allow the finish to dry on the pad). Rinse well under running water. Wring and hang the pad to dry.